OMRON CS1W-MAD44 CS1WMAD44 ANALOG I/O UNIT 4 IN 4 OUT MODULE NEW
$ 387.55
- Description
- Size Guide
Description
Welcome To FibicaFollow Daily Mart on:
OMRON CS1W-MAD44 CS1WMAD44 ANALOG I/O UNIT 4 IN 4 OUT MODULE NEW
Product Description
OMRON CS1W-MAD44 CS1WMAD44 ANALOG I/O UNIT 4 IN 4 OUT MODULE NEW
Availability:
Customize
Usually Ships within 2-4days
Any Questions:
Chat with a Specialist >
Feel free to contact our specialist for any compatibiltiy problems.
Close Notes
Quantity:
1
Buy it Now
If you have any questions, please inform us by eBay message.
Close Notes
Product Detail
Why Daily Mart ?
Payment Method
International Shipping
Return & Warranty
Feature:
Has both analog input and output signals
Ratio conversion function stores the results of positive and negative gradient analog inputs calculated for ratio and bias as analog output values
Hold a maximum of 4 analog input signals and outputs 4 analog output signals in 1 unit
Analog Input functions - Peak value holding, mean value processing and line disconnection detection
Analog Output functions - Output hold function
Specification:
Item
CS1W-MAD44
Applicable PLC model
CS series
Unit type
CS1 Special I/O Unit
Isolation
Between I/O and PLC signals: Photocoupler (No isolation between individual I/O signals.)
External terminals
21-point detachable terminal block (M3 screws)
Power consumption
200 mA max. at 5 VDC, 200 mA max. at 26 VDC
Dimensions (mm) *1
35 ?130 ?126 (W ?H ?D)
Weight
450 g max.
General specifications
Conforms to general specifications for SYSMAC CS-series Series.
Mounting position
CS-series CPU Rack or CS-series Expansion Rack
(Cannot be mounted to a C200H Expansion I/O Rack or a SYSMAC BUS Slave Rack.)
Maximum number of
Units
Units per Rack
(CPU Rack or
Expansion Rack) *2
Power Supply Unit
Maximum number of Units per Rack
C200HW-PA204
C200HW-PA204S
C200HW-PA204R
C200HW-PD024
3 Units max.
C200HW-PA209R
6 Units max.
Units per basic
system
When C200HW-PA209R Power Supply Units only are used:
6 Units max. ?8 Racks = 48 Units max.
Data exchange with
CPU Units
Special I/O Unit Area
CIO 200000 to
CIO 295915
(Words CIO 2000 to
CIO 2959)
Exchanges 10
words of data per
Unit.
CPU Unit to
Analog I/O Unit
Analog output
Peak value hold
Conversion Enable Bit
Analog I/O Unit
to CPU Unit
Analog input
Input disconnection detection
Alarm flags
Internal Special I/O
Unit DM Area
(D20000 to D29599)
Transmits 100
words of data per
Unit at power-up
or when the Unit
is restarted.
CPU Unit to
Analog I/O Unit
Input signal conversion enable/disable,
input signal range setting
Output signal conversion enable/disable,
output signal range setting
Ratio conversion function setting,
constants
Output status for output hold
Mean value function setting
Input
Specifications
Input signal *4
Voltage input
Current input
Number of analog inputs
4
Input signal range *3
1 to 5 V
0 to 5 V
0 to 10 V
- 10 to 10 V
4 to 20 mA
Maximum rated input (for 1 point) *5
?15 V
?30 mA
Input impedance
1 M O min.
250 O (rated value)
Resolution
4,000 (full scale)
Converted output data
16-bit binary data
Accuracy *6
23 ?2 °C
?0.2% of full scale
?0.4% of full scale
0 °C to 55 °C
?0.4% of full scale
?0.6% of full scale
A/D conversion time *7
1.0 ms/point max.
Functions
Mean value processing
Stores the last "n" data conversions in the buffer, and stores
the the mean value of the conversion values.
Buffer number: n = 2, 4, 8, 16, 32, 64
Peak value holding
Stores the maximum conversion value while the Peak Value
Hold Bit is ON.
Input disconnection detection *9
Detects the disconnection and turns ON the Disconnection
Detection Flag.
Output
Specifications
Output signal
Voltage output
Number of analog outputs
4
Output signal range *3
1 to 5 V
0 to 5 V
0 to 10 V
- 10 to 10 V
Output impedance (for 1 point)
0.5 O max.
Max. output current
12 mA
Resolution
4,000 (full scale)
Set data
16-bit binary data
Accuracy *6
23 ?2 °C
?0.3% of full scale
0 °C to 55 °C
?0.5% of full scale
D/A conversion time *7
1.0 ms/point max.
Functions
Output hold function
Outputs the specified output status (CLR, HOLD, or MAX) under
any of the following circumstances.
When the Conversion Enable Bit is OFF. *8
In adjustment mode, when a value other than the output number
is output during adjustment.
When there is an output setting error or a fatal error occurs at
the PLC.
When the CPU Unit is on standby.
When the Load is OFF.
Other
Functions
Ratio conversion function
Stores the results of positive and negative gradient analog
inputs calculated for ratio and bias as analog output values.
Positive gradient: Analog output = A ?Analog input + B
(A = 0 to 99.99, B = 8,000 to 7FFF Hex)
Negative gradient: Analog output = F - A ?Analog input + B
(A = 0 to 99.99, B = 8,000 to 7FFF Hex, F = output range max.
value)
Package Included:
1 x OMRON CS1W-MAD44 CS1WMAD44 ANALOG I/O UNIT 4 IN 4 OUT MODULE NEW
6 months warranty
60 days money back
Life-time support.
Our specialists will be with you during shopping and after-sell. Professional advise and any technical problem will be provided. We will respond any question within
24-hour
normally. Please allow longer time for weekend.
Our logistic team will pack your order safely, make sure the item will be arrived perfectly. And then the parcels will be pass to courier. The total dispatched time will be around
1-2 days
.
We focus on product quality, rather than packaging and marketing, in order to deliver the
finest quality
of product at a fraction cost. We believe that you would like to pay for the item cost except unnecessary costs.
Our product team will keep the products
up-to-date
, which can allows you to purchase the latest and valuable products from our stores. We believe our
Wide Product Range
will be your selection.
How should I make my payment ?
We accept
PayPal
. Your payment is protected by
Buyer Protection
.
Items will be shipped within
1-2 working days
of payment being made.
No mailing payment will be accepted.
How long is the delivery time ?
Total delivery time is split into two parts: Processing and Shipping
Processing time
It takes normally
1-3 business days**
. We will check your order, confirm your payment, verify your address and arrange your shipment during this period of time.
Shipping time
In general, the delivery time of each international courier is as below: